Hillrom and Welch Allyn are a part of Baxter.
text.skipToContent text.skipToNavigation
  • 1(current)
  • 2
32 Results found
Straight-Type Extension Set, Standard Bore, Fixed Collar, 105" (266 cm)
Extension Set Luer Lock Adapter and Fixed Collar. Approximately Volume 14 mL. Approximately lenght 105” (266 cm). Contains DEHP. Sterile Package, Nonpyrogenic.
Nitroglycerin Set, Duo-Vented, CLEARLINK Luer Activated Valve, 60 drops/mL, 103" (2.6 m)
Nitroglycerin Set Duo-Vent Spike with Polyethylene Lined Tubing and CLEARLINK Luer Activated Valve, Male Luer Lock Adapter. Approximately 60 drops/mL. Approximate Length 103" (2.6 m). Contains DEHP. Sterile Fluid Path. The PVC pump segment and outer layer of polyethylene lined tubing contain DEHP: Remainder of fluid path does not contain DEHP.
BURETROL Solution Set, 150 mL Valveless Burette, 4 CLEARLINK Luer Activated Valves, 60  drops/mL, 115" (2.9 m)
BURETROL Solution Set with 150 mLValveless Burette with and 4 CLEARLINK Luer Activated Valves (1 in burette), Male Luer Lock Adapter with Retractable Collar. Approximately 60 drops/mL. Approximate length 115" (2.9 m). Contains DEHP. Fluid path is sterile, nonpyrogenic.
Straight-Type Catheter Extension Set, Microbore, ONE-LINK, Needle-Free IV Connector, Neutral Fluid Displacement, Power Injectable (325 psi/2241 kPa), 7.7" (19.5 cm)
Straight-Type Catheter Extension Set Microbore, ONE-LINK, Needle-Free IV Connector with Neutral Fluid Displacement, Power Injectable (325 psi/2241 kPa) and Male Luer Lock Adapter. Approximate Volume 0.34 mL. Approximate Length 7.7" (19.5 cm). Non-DEHP. Sterile Package, Nonpyrogenic.
INTERLINK SYSTEM EXTENSION SET
INTERLINK SYSTEM EXTENSION SET
3-Port Manifold with Check Valves, 4-Way Stopcock Extension Set, 2 INTERLINK Injection Sites, 41" (103 cm)
3-Port Manifold with Check Valves, Approximate Volume 1.4 mL, Large Bore 4-Way Stopcock Extension Set with Rotating Male Luer Lock, 2 INTERLINK Injection Sites, Male Luer Lock Adapter with Retractable Collar. Approximate Volume 6.1 mL. Approximate length 41" (103 cm). Contains DEHP. Sterile package, nonpyrogenic.
CL BURETROL 150ML 3 VALV LUERSOUPAPE 60G/ML 2,6M 48/CA
CL BURETROL 150ML 3 VALV LUERSOUPAPE 60G/ML 2,6M 48/CA
CONTINU-FLO Solution Set, Non-Vented, 0.2 Micron Filter, 2 INTERLINK Injection Sites, Backcheck Valve. 10 drops/mL. 105" (2.7 m)
CONTINU-FLO Solution Set with Non-Vented Spike, 0.2 Micron Filter, 2 INTERLINK Injection Sites, Backcheck Valve and Male Luer Lock Adapter Retractable Collar. Approximately 10 drops/mL. Approximate Length 105" (2.7 m). Contains DEHP. Fluid path is sterile, nonpyrogenic.
CONTINU-FLO Solution Set, Non-Vented, 2 CLEARLINK Luer Activated Valves, Backcheck Valve plus Stopcock Manifold and 1 CLEARLINK Luer Activated Valves Extension Set. Approx. 10 drops/mL
CONTINU-FLO Solution Set with Non-Vented Spike, 2 CLEARLINK Luer Activated Valves, Backcheck Valves, Male Luer Lock Adapter with Retractable Collar. Approximately 10 drops/mL. Approximate length 88" (2.2 m). Plus Large Bore 4-Way Stopcocks Manifold Extension Set with CLEARLINK Luer Activated Valve and Male Luer Lock Adapter with Retractable Collar, Approximate Volume 5.6 mL. Approximate Length 35" (88 cm). Contains DEHP. Sterile package, nonpyrogenic.
INTERLINK VENTED SECONDARY MEDSET, W/LEVER LOCK
INTERLINK VENTED SECONDARY MEDSET, W/LEVER LOCK
3-Port Manifold with Check Valves, 4-Way Stopcock Extension Set, 2 CLEARLINK Luer Activated Valves, 40" (101 cm)
3-Port Manifold with Check Valves, Approximate Volume 1.4 mL, Large Bore 4-way Stopcock Extension Set with Rotating Male Luer Lock, 2 CLEARLINK Luer Activated Valves, Male Luer Lock Adapter with Retractable Collar. Approximate Volume 6.2 mL. Approximate Length 40" (101 cm). Contains DEHP. Sterile Package, nonpyrogenic.
CONTINU-FLO Solution Set, Non-Vented, 2 INTERLINK Injection Sites. Plus 4-Way Stopcock Manifold Extension Set with INTERLINK Injection Site
CONTINU-FLO Solution Set with Non-Vented Spike, 2 INTERLINK Injection Sites, Backcheck Valve and Male Luer Lock Adapter with Retractable Collar. Approximately 10 drops/mL. Approximate Length 89" (2.3 m). Plus Large Bore 4-Way Stopcocks Manifold Extension Set with INTERLINK Injection Site and Male Luer Lock Adapter with Retractable Collar. Approximate Volume 5.5 mL. Approximate Length 35" (90 cm). Contains DEHP. Sterile package, nonpyrogenic.
BURETROL Solution Set, 150 mL Burette Drip Chamber Filter Valve, 3 INTERLINK Injection Sites, 60 drops/ mL, 105" (2.7 m)
BURETROL Solution Set with 150 mL Burette Drip Chamber Filter Valve and 3 INTERLINK Injection Sites (1 in burette), Male Luer lock adapter with Retractable Collar. Approximately 60 drops/ mL. Approximate length 105" (2.7 m). Contains DEHP. Fluid path is sterile, nonpyrogenic.
Paclitaxel Set, Non-Vented, 0.2 Micron Filter, CLEARLINK Luer Activated Valve, 10 drops/mL, 107" (2.7 m)
Paclitaxel Set Non-Vented Spike with Polyethylene Lined Tubing and CLEARLINK Luer Activated Valve, 0.2 Micron Filter, Male Luer Lock Adapter. Approximately 10 drops/mL. Approximate Length 107" (2.7 m). Non-DEHP Pump Segment. Sterile Fluid Path. Fluid path does not contain DEHP: Outer layer of polyethylene lined tubing contains DEHP.
CONTINU-FLO Solution Set , Non-Vented, 2 CLEARLINK Luer Activated Valves. Plus 4-Way Stopcock Manifold Extension Set with CLEARLINK Luer Activated Valve
CONTINU-FLO Solution Set with Non-Vented Spike, 2 CLEARLINK Luer Activated Valves, Backcheck Valve and Male Luer Lock Adapter with Retractable Collar. Approximately 10 drops/mL. Approximate length 88" (2.2 m). Plus Large Bore 4-Way Stopcock Manifold Extension Set with CLEARLINK Luer Activated Valve and Male Luer Lock Adaptor with Retractable Collar. Approximate Volume 6.1 mL. Approximate Length 36" (92 cm). Contains DEHP. Sterile package, nonpyrogenic.
Straight-Type Catheter Extension Set, Microbore, ONE-LINK, Bonded Needle-free IV Connector, Neutral Fluid Displacement, Power Injectable (325 psi/2241 kPa), 8.5 " (21.6 cm)
Straight-Type Catheter Extension Set Microbore, ONE-LINK, Bonded Needle-free IV Connector with Neutral Fluid Displacement, Power Injectable (325 psi/2241 kPa) and Male Luer Lock Adapter with Retractable Collar. Approximate Volume 0.30 mL. Approximate Length 8.5 " (21.6 cm). Non-DEHP. Sterile Package, Nonpyrogenic.
Paclitaxel Set, Vented, 0.2 Micron Filter, CLEARLINK Luer Activated Valve, 10 drops/mL, 107" (2.7 m)
Paclitaxel Set Vented Spike with Polyethlyene Lined Tubing and CLEARLINK Luer Activated Valve, 0.2 Micron Filter, Male Luer Lock Adapter. Approximately 10 drops/mL. Approximate Length 107" (2.7 m). Non-DEHP Pump Segment. Sterile Fluid Path. Fluid path does not contain DEHP; outer layer of polyethylene lined tubing contains DEHP.
Nitroglycerin Set, DUO-VENT, INTERLINK Injection Site, 60 drops/mL, 103" (2.6 m)
Nitroglycerin Set DUO-VENT Spike with Polyethylene Lined Tubing and INTERLINK Injection Site, Male Luer Lock Adapter, Approximately 60 drops/mL. Approximate length 103" (2.6 m). Sterile Fluid Path. The PVC pump segment and outer layer of polyethylene lined tubing contain DEHP; Remainder of fluid path does not contain DEHP.
  • 1(current)