Hillrom and Welch Allyn are a part of Baxter.
text.skipToContent text.skipToNavigation
  • 1(current)
  • 2
  • 3
39 Results found
INTERLINK BASIC SET 92 IN.
INTERLINK BASIC SET 92 IN.
Solution Set, Non-Vented, CLEARLINK Luer Activated Valve, 10 drops/mL, 76" (1.9 m)
Solution Set with Non-Vented Spike, CLEARLINK Luer Activated Valve and Male Luer Lock Adapter with Retractable Collar. Approximately 10 drops/mL. Approximate Length 76" (1.9 m). Contains DEHP. Fluid path is sterile, nonpyrogenic.
Solution Set, Non-Vented, 10 drops/mL,  69" (1.7 m), Sterile package
Solution Set with Non-Vent Spike and Male Luer Lock Adapter. Approximately 10 drops/mL. Approximate Length 69" (1.7 m). Contains DEHP. Sterile package, nonpyrogenic.
CONTINU-FLO Solution Set, Vented, 2 CLEARLINK Luer Activated Valves, Backcheck Valve. 60 drops/mL. 104" (2.6m)
CONTINU-FLO Solution Set with Vented Spike, 2 CLEARLINK Luer Activated Valves, Backcheck Valve and Male Luer Lock Adapter with Retractable Collar. Approximately 60 drops/mL. Approximate Length 104" (2.6m). Contains DEHP. Fluid path is sterile, nonpyrogenic.
Solution Set, DUO-VENT, 0.2 Micron Filter, CLEARLINK Luer Activated Valve, 10 drops/mL, 102" (2.6 m), Non-DEHP
Solution Set with DUO-VENT Spike, 0.2 Micron Downstream Filter, CLEARLINK Luer Activated Valve and Male Luer Lock Adapter with Retractable Collar. Approximately 10 drops/mL. Approximate Length 102" (2.6 m). Non-DEHP. Fluid path is sterile, nonpyrogenic.
INTERLINK BASIC SOLN SET 2 INJSITES 10 DPM
INTERLINK BASIC SOLN SET 2 INJSITES 10 DPM
Solution Set, Non-Vented, 10 drops/mL,  101" (2.6 m)
Solution Set with Non-Vent Spike and Male Luer Lock Adapter. Approximately 10 drops/mL. Approximate Length 101" (2.6 m). Contains DEHP. Fluid path is sterile, nonpyrogenic.
INTERLINK SYSTEM BASIC SOLNSET INJ SITE
INTERLINK SYSTEM BASIC SOLNSET INJ SITE
CONTINU-FLO Solution Set, Non-Vented, 3 INTERLINK Injection Sites, Backcheck Valve. 10 drops/mL. 110" (2.8 m)
CONTINU-FLO Solution Set with Non-Vented Spike, 3 INTERLINK Injection Sites, Backcheck Valve and Male Luer Lock Adapter with Retractable Collar. Approximately 10 drops/mL. Approximate Length 110" (2.8 m). Contains DEHP. Fluid path is sterile, nonpyrogenic.
Solution Set, Non-Vented, 60 drops/mL, 109" (2.8 m). Sterile Package
Solution Set with Non-Vented Spike and Male Luer Lock Adapter with Retractable Collar. Approximately 60 drops/mL. Approximate Length 109" (2.8 m). Contains DEHP. Sterile package, nonpyrogenic.
CONTINU-FLO Solution Set, Non-Vented, 3 CLEARLINK Luer Activated Valves, Backcheck Valve, Retractable Collar, 10 drops/mL, 109" (2.8 m), Non-DEHP
CONTINU-FLO Solution Set with Non-Vented, 3 CLEARLINK Luer Activated Valves, Backcheck Valve and Male Luer Lock Adapter with Retractable Collar. Approximately 10 drops/mL. Approximate Length 109" (2.8 m). Non-DEHP. Fluid path is sterile, nonpyrogenic.
INTERLINK SOLN SET INJ. SITE L/L 60 DPM
INTERLINK SOLN SET INJ. SITE L/L 60 DPM
CONTINU-FLO Solution Set, DUO-VENT, 3 CLEARLINK Luer Activated Valves, Backcheck Valve, 10 drops/mL, 120"
CONTINU-FLO Solution Set with DUO-VENT Spike, 3 CLEARLINK Luer Activated Valves, Backcheck Valve and Male Luer Lock Adapter with Retractable Collar. Approximately 10 drops/mL. Approximate Length 120". Contains DEHP. Fluid path is sterile, nonpyrogenic.
CONTINU-FLO Solution Set, DUO-VENT, 2 CLEARLINK Luer Activated Valves, Backcheck Valve. 10 drops/mL. 114"
CONTINU-FLO Solution Set with DUO-VENT Spike, 2 CLEARLINK Luer Activated Valves, Backcheck Valve, Male Luer Lock Adapter with Retractable Collar. Approximately 10 drops/mL. Approximate Length 114". The PVC pump segment contains DEHP: Remainder of set does not contain DEHP. Fluid path is sterile, nonpyrogenic.
IV Fat Emulsion Administration Set, Non-Vented, 10 drops/mL, 86" (2.2 m), Non-DEHP
IV Fat Emulsion Administration Set with Non-Vented Spike and Male Luer Lock Adapter with Retractable Collar. Approximately 10 drops/mL. Approximate Length 86" (2.2 m). Non-DEHP. Fluid path is sterile, nonpyrogenic.
CONTINU-FLO Solution Set, Non-Vented, CLEARLINK Luer Activated Valve, Backcheck Valve, 10 drops/mL, 106" (2.7 m)
CONTINU-FLO Solution Set with Non-Vented Spike, CLEARLINK Luer Activated Valve, Backcheck Valve and Male Luer Lock Adapter with Retractable Collar. Approximately 10 drops/mL. Approximate Length 106" (2.7 m). Contains DEHP. Fluid path is sterile, nonpyrogenic.
INTERLINK VENTED BASIC SOLN SET
INTERLINK VENTED BASIC SOLN SET
CONTINU-FLO Solution Set, Non-Vented, 3 CLEARLINK Luer Activated Valves, Backcheck Valve, Retractable Collar., 10 drops/mL, 120"
CONTINU-FLO Solution Set with Non-Vented Spike, 3 CLEARLINK Luer Activated Valves, Backcheck Valve and Male Luer Lock Adapter with Retractable Collar. Approximately 10 drops/mL. Approximate Length 120". Contains DEHP. Fluid path is sterile, nonpyrogenic.
  • 1(current)
  • 2
  • 3