Item #: H938175
Automated Compounding Device Inlet. Vented, Micro-Volume Inlet for use with Small Vials. Tubing set with push-on connector on one end to attach to the valve set and a vented spike on the opposite end to attach the source container. Sterile. Non-DEHP.
Material per IFU:
Inlet Connector: ABS
Tubing: Non-DEHP PVC
Outlet Connector: TPE
Materials: Acrylonitrile butadiene styrene (ABS), polyvinyl chloride (PVC), thermoplastic elastomer (TPE), polycarbonate (PC)
Item #: H938176
Automated Compounding Device Inlet. Micro-Volume Inlet with Luer Lock End. For use with syringes. Tubing set with push-on connector on one end to attach to valve set and a luer lock on the opposite end to attach the source container. Sterile. Non-DEHP.
Material per IFU:
Inlet Connector: ABS
Tubing: Non-DEHP PVC
Outlet Connector: TPE
Materials: Acrylonitrile butadiene styrene (ABS), polyvinyl chloride (PVC), thermoplastic elastomer (TPE), polycarbonate (PC)
INFUVITE Pediatric Multiple Vitamins for Infusion. Pharmacy Bulk Package. Not For Direct Infusion. Available in boxes containing 2 vials – 1 each of Vial 1 (40 mL Fill in 50 mL Vial) and Vial 2 (10 mL). Mix contents of Vial 2 with Vial 1 to provide 10 single 5 mL doses. NDC 54643-5647-0
INFUVITE Pediatric Multiple Vitamins for infusion. Single dose package. Available in boxes containing 10 vials – 5 each of Vial 1 (4 mL) and Vial 2 (1 mL), one Vial 1 plus one Vial 2 to be used for a single dose. NDC 54643-5646-1
INFUVITE Adult Multiple Vitamins for infusion. Single dose package. Available in boxes containing 10 vials - 5 each of Vial 1 (5 mL) and Vial 2 (5 mL), one Vial 1 plus one Vial 2 to be used for a single dose. NDC 54643-5649-1
Sterile EXACTAMIX 1200 Valve Set. For use with EXACTAMIX 1200 Compounder only. Used to connect up to 12 Source Ingredients. Sterile. Non-DEHP.
Automated Compounding Device Inlet. Micro-Volume Inlet with Large Bore Spike. Tubing set with push-on connector on one end to attach to the valve set and a large bore spike on the opposite end to attach the source container. For use with EXACTAMIX Compounders. Sterile. Non-DEHP.
Material per IFU:
Inlet Connector: ABS
Tubing: Non-DEHP PVC
Outlet Connector: TPE
Materials: Acrylonitrile butadiene styrene (ABS), polyvinyl chloride (PVC), thermoplastic elastomer (TPE), polycarbonate (PC)
Item #: A662250003
The QNRG+ Flow-REE (Pneumotech) is a single use flowmeter placed in series in the patient circuit, allows the in-line measurement of ventilatory parameters (Vt, RF and VE). Required for VENT mode testing of mechanichally intubated patients.
Item #: H93867
EXACTAMIX Needle Port Adapter. Adapts the compounder Valve Set to allow pumping into a container without large bore connection. Packaged individually. Sterile.
CLINOLIPID injection is indicated in adults and pediatric patients, including term and preterm neonates as a source of calories and essential fatty acids for parenteral nutrition (PN) when oral or enteral nutrition is not possible, insufficient, or contraindicated.
CLINIMIX (amino acids in dextrose) Injections and CLINIMIX E (amino acids with electrolytes in dextrose with calcium) Injections are indicated as a source of calories and protein (and electrolytes for CLINIMIX E) for patients requiring parenteral nutrition when oral or enteral nutrition is not possible, insufficient, or contraindicated. CLINIMIX and CLINIMIX E may be used to treat negative nitrogen balance in patients.
Item #: C026780107
The Canopy Hose is used when CANOPY mode testing is performed with the QNRG+ Metabolic Monitor to connect the Canopy to the QNRG+ Monitor. The Hose is reusable and must be cleaned or replaced monthly (use of antibacterial/antiviral filter and canopy veils are also required but sold separately).
Item #: H938905
EVA Dual Chamber Empty Container, 3000 mL Total Capacity. 500 mL upper chamber, 2500 mL lower chamber. For use in the administration of intravenous solutions. Sterile. Non-DEHP.
Material per IFU:
Bag: Ethylene-vinyl acetate (EVA)
Fill Port:
Tube: EVA
Connector/Cap: acrylonitrile butadiene styrene (ABS)
Administration Port: EVA: DEHP-free polyvinyl chloride (PVC)
Additive Port:
Tube: EVA
Septum: Poly-isoprene rubber
Cap / Septum retaining ring: polypropylene
Non-Reopening Clamp: Styrene-butadiene copolymer
Item #: H938901
EVA Dual Chamber Empty Container, 1500 mL Total Capacity. 250 mL upper chamber, 1250 mL lower chamber. For use in the administration of intravenous solutions. Sterile. Non-DEHP.
Material per IFU:
Bag: Ethylene-vinyl acetate (EVA)
Fill Port:
Tube: EVA
Connector/Cap: acrylonitrile butadiene styrene (ABS)
Administration Port: EVA: DEHP-free polyvinyl chloride (PVC)
Additive Port:
Tube: EVA
Septum: Poly-isoprene rubber
Cap / Septum retaining ring: polypropylene
Non-Reopening Clamp: Styrene-butadiene copolymer
Item #: H938735
EXACTAMIX Empty EVA (ethylene vinyl acetate) Calibration Bag, 1000 mL. Sterile Fluid Path. Non-DEHP. Used for calibration during the setup of an automated compounding device.
Material per IFU:
Bag: Ethylene-vinyl acetate (EVA)
Fill Port:
Tube: EVA
Connector/Cap: acrylonitrile butadiene styrene (ABS)
Administration Port: EVA: DEHP-free polyvinyl chloride (PVC)
Additive Port:
Tube: EVA
Septum: Poly-isoprene rubber
Cap / Septum retaining ring: polypropylene
Non-Reopening Clamp: Styrene-butadiene copolymer
Item #: C006000211
Calibration syringe with a certified volume of 3 liters allows calibration of Q-NRG blower and external turbine.
Photoprotective EXACTAMIX Empty EVA (ethylene vinyl acetate) Bag, 3000 mL. Manufactured by VALMED and distributed by Baxter Healthcare. Used for large-volume sterile solutions. Non-reopening clamp attached. Non-vented cap for the fill port included in sterile blister. For use with ExactaMix and ExactaMix Pro Compounder. Non-DEHP.