You searched for "YEAR BO 80 DROPS"
Item #: 480112BAX
Long Duration elastomeric infusion pump 400 ml volume, 5 ml/hr flow rate, 80 hour duration.
Eos Mvlt80-1001-S77 Power Supply Circuit Board
Item #: 703611
Obsolete part - No Longer Available
Welch Allyn parts meet OEM requirements and standards for fit, function and quality. Use genuine OEM parts and accessories as replacements or to repair Welch Allyn devices.
Item #: 2H6401
Solution Set with Non-Vented Spike, INTERLINK Injection Site, Lever Lock Cannula (detached) and Male Luer Lock Adapter with Retractable Collar. Approximately 10 drops/mL. Approximate Length 76" (1.9 m). Non-DEHP. Fluid path is sterile, nonpyrogenic.
Solution Set with Non-Vent Spike and Male Luer Lock Adapter. Approximately 10 drops/mL. Approximate Length 101" (2.6 m). Contains DEHP. Fluid path is sterile, nonpyrogenic.
Item #: 2C7557
Paclitaxel Set Vented Spike with Polyethylene Lined Tubing and INTERLINK Injection Site, 0.2 Micron Filter, Male Luer Lock Adapter. Approximately 10 drops/mL. Approximate length 107" (2.7 m). Non-DEHP Pump Segment. Sterile Fluid Path. Fluid path does not contain DEHP; outer layer of polyethylene lined tubing contains DEHP.
Item #: 4C7750
Add-On Large Standard Blood Filter 170 to 260 Micron Filter, Approximately 15 drops per mL, Approximate Length 10" (26 cm). Contains DEHP, Fluid path is sterile.
Item #: 2C6519
CONTINU-FLO Solution Set with Non-Vented Spike, 2 INTERLINK Injection Sites, Backcheck Valve and Male Luer Lock Adapter with Retractable Collar. Approximately 10 drops/mL. Approximate Length 89" (2.2 m). Contains DEHP. Fluid path is sterile, nonpyrogenic.
Item #: 2R8401
Solution Set with Non-Vented Spike, CLEARLINK Luer Activated Valve and Male Luer Lock Adapter with Retractable Collar. Approximately 10 drops/mL. Approximate Length 76 (1.9 m). Non-DEHP. Fluid path is sterile, nonpyrogenic.
Item #: 2C7451
Secondary Medication Set with INTERLINK Lever Lock Cannula (detached), Male Luer Lock Adapter. Hanger for primary solution container is provided. Approximately 10 drops/mL Approximate length 37 (95 cm). Contains DEHP. Fluid path is sterile, nonpyrogenic
Item #: 2C7462
Secondary Medication Set with DUO-VENT Spike, Male Luer Lock Adapter. Hanger for primary solution container is provided. For use with rigid nonvented and flexible containers and the CLEARLINK System. Approximately 10 drops/mL. Approximate length 37" (93 cm). Contains DEHP. Fluid path is sterile, nonpyrogenic.
Item #: 2C7461
Secondary Medication Set, Male Luer Lock Adapter. For use with CLEARLINK System. Hanger for primary solution container is provided. Approximately 10 drops/mL. Approximate length 37 (93 cm). Contains DEHP. Fluid path is sterile, nonpyrogenic.
Secondary Medication Set, DUO-VENT, INTERLINK Luer Lock Cannula (detached). 10 drops/mL. 37" (95 cm)
Item #: 2C7452
Secondary Medication Set with DUO-VENT Spike, INTERLINK Luer Lock Cannula (detached), Male Luer Lock Adapter. Hanger for primary solution container is provided. Approximately 10 drops/mL. Approximate length 37" (95 cm). Contains DEHP. Fluid path is sterile, nonpyrogenic.
Paclitaxel Set, Vented, 0.2 Micron Filter, CLEARLINK Luer Activated Valve, 10 drops/mL, 107" (2.7 m)
Item #: 2C8857
Paclitaxel Set Vented Spike with Polyethlyene Lined Tubing and CLEARLINK Luer Activated Valve, 0.2 Micron Filter, Male Luer Lock Adapter. Approximately 10 drops/mL. Approximate Length 107" (2.7 m). Non-DEHP Pump Segment. Sterile Fluid Path. Fluid path does not contain DEHP; outer layer of polyethylene lined tubing contains DEHP.
Added to Your Cart
Product Availability by Store Location
Hours


