Hillrom and Welch Allyn are a part of Baxter.
text.skipToContent text.skipToNavigation

You searched for "your bo 80 drop"

Did you mean: your bo 80 drops?
  • 1(current)
  • 2
  • 3
113 Results found
    Automated Compounding Device Inlet. Vented High-Volume Inlet for Non-Vented Bottles.
    Automated Compounding Device Inlet. Vented, High-Volume Inlet for Non-Vented Bottles. Tubing set with push-on connector on one end to attach to the valve set and a vented spike on the opposite end to attach the source container. Sterile. Non-DEHP. Material per IFU: Inlet Connector: ABS Tubing: Non-DEHP PVC Outlet Connector: TPE Materials: Acrylonitrile butadiene styrene (ABS), polyvinyl chloride (PVC), thermoplastic elastomer (TPE), polycarbonate (PC)
    QNRG+ Reusable Hydrophobic Filter for Alternative Ventilator mode setup
    When there is an active heated humidifier, the Ventilator Mode test can also be performed using the ICU Patient Connector and the Hydrophobic Filter. The ICU Patient Connector replaces the Standard Filter minimizing dead space and resistance added to the circuit and thus improving patient comfort. The Hydrophobic Filter is then required to prevent water condensation to get into the device, due to the absence of the Standard Filter. Reusable: must be replaced daily or after 5 tests, whichever occurs first.
    Automated Compounding Device Inlet. Non-Vented High Volume  Inlet for Bags or Vented Bottles.
    Automated Compounding Device Inlet. Non-Vented High Volume Inlet for bags or vented bottles. Tubing sets with push-on connector on one end (to attach to the fluid selector valve) and a spike or other appropriate connector on the opposite end to attach the source container. Sterile. Non-DEHP. Material per IFU: Inlet Connector: Rigid PVC Tubing: Non-DEHP PVC Outlet Connector: TPE Materials: Acrylonitrile butadiene styrene (ABS), polyvinyl chloride (PVC), thermoplastic elastomer (TPE), polycarbonate (PC)
    Automated Compounding Device Inlet. Micro-Volume, Large Bore Spike.
    Automated Compounding Device Inlet. Micro-Volume Inlet with Large Bore Spike. Tubing set with push-on connector on one end to attach to the valve set and a large bore spike on the opposite end to attach the source container. For use with EXACTAMIX Compounders. Sterile. Non-DEHP. Material per IFU: Inlet Connector: ABS Tubing: Non-DEHP PVC Outlet Connector: TPE Materials: Acrylonitrile butadiene styrene (ABS), polyvinyl chloride (PVC), thermoplastic elastomer (TPE), polycarbonate (PC)
    EXACTAMIX Large Bore Cap, Internal Thread
    EXACTAMIX Large Bore Cap, Internal Thread. Threaded cap for closing container-filling tubes and bag ports. Sterile. Non-DEHP
    EXACTAMIX Large Bore Cap, External Thread.
    EXACTAMIX Large Bore Cap, External Thread. Threaded cap for closing container-filling tubes and bag ports. Sterile. Non-DEHP. Material per IFU: Acrylonitrile butadine styrene (ABS)
    QNRG+ Metabolic Monitor
    QNRG+ is a registered trademark of COSMED.
    View Product Details
    20% CLINOLIPID (Lipid Injectable Emulsion, USP) 100 mL
    20% CLINOLIPID (Lipid Injectable Emulsion, USP) 100 mL, in a CLARITY polyolefin bag. CLINOLIPID is 80% Olive Oil and 20% Soybean oil. Sterile. Single Use Only. NDC:0338-9540-01 bag. Please refer to full Prescribing Information, including Boxed Warning.
    20% CLINOLIPID (Lipid Injectable Emulsion, USP) 500 mL
    20% CLINOLIPID (Lipid Injectable Emulsion, USP) 500 mL, in a CLARITY polyolefin bag. CLINOLIPID is 80% Olive Oil and 20% Soybean oil. Sterile. Single Use Only. NDC:0338-9540-03 bag. Please refer to full Prescribing Information, including Boxed Warning.
    20% CLINOLIPID (Lipid Injectable Emulsion, USP) 1000 mL
    20% CLINOLIPID (Lipid Injectable Emulsion, USP) 1000 mL, in a CLARITY polyolefin bag. CLINOLIPID is 80% Olive Oil and 20% Soybean oil. Sterile. Single Use Only. NDC:0338-9540-04 bag. Please refer to full Prescribing Information, including Boxed Warning.
    20% CLINOLIPID (Lipid Injectable Emulsion, USP) 250 mL
    20% CLINOLIPID (Lipid Injectable Emulsion, USP) 250 mL, in a CLARITY polyolefin bag. CLINOLIPID is 80% Olive Oil and 20% Soybean oil. Sterile. Single Use Only. NDC:0338-9540-02 bag. Please refer to full Prescribing Information, including Boxed Warning.
    INFUVITE Pediatric Multiple Vitamins for Infusion. Pharmacy Bulk Package
    INFUVITE Pediatric Multiple Vitamins for Infusion. Pharmacy Bulk Package. Not For Direct Infusion. Available in boxes containing 2 vials – 1 each of Vial 1 (40 mL Fill in 50 mL Vial) and Vial 2 (10 mL). Mix contents of Vial 2 with Vial 1 to provide 10 single 5 mL doses. NDC 54643-5647-0
    QNRG+ Antibacterial/Antiviral Filter for Canopy and Mask Modes
    The single use filter is used when canopy mode or mask mode testing is performed with the QNRG+ Metabolic Monitor. The purpose of the filter is to avoid cross-contamination. Inquiries regarding PVC/DEHP status should be referred to COSMED.
    Sterile EXACTAMIX 1200 Valve Set. For use with EXACTAMIX 1200 Compounder only.
    Sterile EXACTAMIX 1200 Valve Set. For use with EXACTAMIX 1200 Compounder only. Used to connect up to 12 Source Ingredients. Sterile. Non-DEHP.
    QNRG+ Clamp for Pole/Rail with VESA mounting plate
    The QNRG+ Pole Clamp allows the QNRG+ Monitor to be placed on its corresonding Pole Cart for easy transportation to patient side.
    QNRG+ Veils for Canopy Hood LARGE
    A single use veil is used when CANOPY mode testing is performed with the QNRG+ Metabolic Monitor to enclose the CANOPY and protect from air leaks during patient testing
    Sterile EXACTAMIX 2400 Valve Set. For use with EXACTMIX 2400 Compounder only.
    Sterile EXACTAMIX 2400 Valve Set. For use with EXACTMIX 2400 Compounder only. Used to connect up to 24 Source Ingredients. Sterile. Non-DEHP. Material per IFU: Port Caps: PVC (polyvinyl chloride)
    INFUVITE Pediatric, Multiple Vitamins for infusion. Single dose package
    INFUVITE Pediatric Multiple Vitamins for infusion. Single dose package. Available in boxes containing 10 vials – 5 each of Vial 1 (4 mL) and Vial 2 (1 mL), one Vial 1 plus one Vial 2 to be used for a single dose. NDC 54643-5646-1
  • 1(current)
  • 2
  • 3