Hillrom and Welch Allyn are a part of Baxter.
Smart Pump Infusion Technology; EMR integration, Configurable dose error reduction system (DERS), Single step titration, Flow check at run, Secondary container infusion check.
Kompatible Teile anzeigen
ONE-LINK Needle-free IV Connector with Neutral Fluid Displacement, Power Injectable (325 psi / 2241 kPa). Approximate volume 0.08 mL. Non-DEHP. Non-PVC. Sterile Package.
Kompatible Teile anzeigen
The Starling non-invasive fluid management monitoring system provides continuous hemodynamic monitoring and empowers fluid management across the continuum of care: ICU, ED, RRT and OR A portable and lightweight touch screen monitor: H: 8.7, W: 11.4, D: 7.4 9.5 lbs., 10.4 6 hour battery life Includes Starling Patient Cable, Starling Power Cable and Non-Invasive Blood Pressure Module
Kompatible Teile anzeigen
CLEARLINK Luer Activated Valve. Approximate volume 0.25 mL. Non-DEHP. Non-PVC. Sterile Package.
Kompatible Teile anzeigen
The SimplFusor Elastomeric Pump (Long infusion time article) is intended for continuous infusion of medications for general infusion use including pain management.
• Routes of administration: intravenous and subcutaneous.
Teilenr.: 480092BAX
Long Duration elastomeric infusion pump 270ml volume, 5ml/hr flow rate, 54hour duration
Teilenr.: 481022BAX
Short Duration elastomeric infusion pump 250ml volume, 500ml/hr flow rate, 30minute duration
Teilenr.: 7N8376K
Y-Type Catheter Extension Set Standard Bore, ONE-LINK Needle-free IV Connector with Neutral Fluid Displacement, and Male Luer Lock Adapter with Retractable Collar. Approximate Volume 1.4 mL. Approximate Length 8.8 " (22.3 cm). Non-DEHP. Sterile Package, Nonpyrogenic.
Teilenr.: 2N3385
Integrated Blood Set with Tip Protector, Spike, Drip Chamber with Blood Filter, On/Off clamp, Luer Activated Valve (CLEARLINK), Luer Lock Adapter, and Vented Cap. Approx. Length: 71" (180 cm) from Luer Activated Valve to Vented Cap. Approx. Priming Volume: 6.3 ml from Luer Activated Valve to Vented Cap. Sterile. Sterilized using irradiation. Non-pyrogenic.
Teilenr.: 2H5660
Extension Set with 0.2 Micron Filter and Male Luer Lock Adapter with Retractable Collar. Approximate Volume 3.9 mL. Approximate Length 9.5" (24 cm). Non-DEHP. Fluid path is sterile, Nonpyrogenic.
Teilenr.: 2H8603
Extension Set with 1.2 Micron Filter, CLEARLINK Luer Activated Valve and Male Luer Lock Adapter. Approximate Volume 5.3 mL. Approximate Length 19" (47 cm). Non-DEHP. Fluid Path is sterile, Nonpyrogenic.
Teilenr.: 2R8401
Solution Set with Non-Vented Spike, CLEARLINK Luer Activated Valve and Male Luer Lock Adapter with Retractable Collar. Approximately 10 drops/mL. Approximate Length 76" (1.9 m). Non-DEHP. Fluid path is sterile, nonpyrogenic.
Teilenr.: 481036BAX
Short Duration elastomeric infusion pump 50 ml volume, 50 ml/hr flow rate, 60 minute duration
Zum Warenkorb hinzugefügt
Produktverfügbarkeit nach Geschäftsstandort
Uhrzeiten