Hillrom and Welch Allyn are a part of Baxter.
Item #: 2R8486
Solution Set with Non-Vented Spike, 1.2 Micron Downstream Filter, CLEARLINK Luer Activated Valve and Male Luer Lock Adapter with Retractable Collar. Approximately 10 drops/mL. Approximate Length 107" (2.7 m). Non-DEHP. Fluid path is sterile, nonpyrogenic.
Item #: 3600032402
Labetalol Hydrochloride Injection USP, 200 mg/40 mL (5 mg/mL) Multi-Dose Vial (1 x 40 mL). For Intravenous Use. Carton NDC 36000-324-02
Item #: 4306603505
Verapamil Hydrochloride Injection, USP, 10 mg/4 mL (2.5 mg/mL) single-dose vials (5 x 4 mL): NDC 43066-035-05
Item #: 481013BAX
Short Duration elastomeric infusion pump 100 ml volume, 200 ml/hr flow rate, 30 minute duration.
Item #: 481172BAX
Long Duration elastomeric infusion pump 500 ml volume, 20 ml/hr flow rate, 25 hour duration.
Item #: 7N8330K
3 Lead Catheter Extension Set, Microbore ONE-LINK Bonded Needle-free IV Connector with Neutral Fluid Displacement, and Male Luer Lock Adapter. Approximate volume 0.73 mL. Approximate Length 8.0" (20.4 cm). Non-DEHP. Sterile Package, Nonpyrogenic.
Solution Set with DUO-VENT Spike, CLEARLINK Luer Activated Valve and Male Luer Lock Adapter with Retractable Collar. Approximately 10 drops/mL. Approximate Length 104" (2.6m). Contains DEHP. Fluid path is sterile, nonpyrogenic.
Item #: AIN03237
Succinylcholine Chloride Injection, USP 100 mg/5 mL (20 mg/mL) in Single-dose, pre-filled syringe: NDC: 43066-127-05 Please refer to full Prescribing Information, including Indications and Boxed Warning
Item #: DG1016SN
DURA-GUARD Dural Repair Patch is prepared from bovine pericardium which is cross-linked with glutaraldehyde. DURA-GUARD Dural Repair Patch is chemically sterilized using ethanol and propylene oxide. DURA-GUARD Dural Repair Patch is packaged in a container filled with sterile, non-pyrogenic water containing propylene oxide.
Item #: EADB9524
20% CLINOLIPID (Lipid Injectable Emulsion, USP) 1000 mL, in a CLARITY polyolefin bag. CLINOLIPID is 80% Olive Oil and 20% Soybean oil. Sterile. Single Use
Only. NDC:0338-9540-04 bag. Please refer to full Prescribing Information, including Boxed Warning.
0.9% Sodium Chloride Injection, USP, 100 mL MINI-BAG Plus Container. For use with single dose powdered or liquid (up to 10 mL) drug vials with standard 20 mm closures. Single Pack. NDC 0338-9159-30
Item #: FT12225
FLO-THRU Intraluminal Shunt, is a sterile, single use, disposable one-piece radiopaque silicone tube with atraumatic bulbs shaped at each end. Openings at the ends of the bulbs allow blood to flow through the shunt and distal to the anatomosis. A radiopaque tab, which identifies the outer diameter of the bulbs, is attached to the shunt by a tether to faciliate positioning and removal of the shunt.
Item #: PG1225
Peri-Guard Repair Patch is derived from bovine pericardium procured from cattle originating in the United States. The pericardium is cross-linked with glutaraldehyde and treated with 1 molar sodium hydroxide for a minimum of 60 minutes at 20-25°C (68-77°F).
Item #: RM0818BIO
VERITAS Collagen Matrix is an implantable biologic mesh comprised of non-crosslinked bovine pericardium. VERITAS is packaged in an inner sterile pouch and outer non-sterile pouch. The contents of the unopened, undamaged container are sterile. Single Use Only. VERITAS is available in 11 sizes. Shown here: 6X8cm
.
Item #: TY20BAEO
Oral / Enteral Syringe 20mL Amber. Non-Luer Slip. Tip Cap Included. Non Sterile. Pharmacy Pack (25/pack 200/case)
Item #: 74MT-B
Welch Allyn Connex Spot Monitor with SureBP Non-invasive Blood Pressure, Masimo SpO2, SureTemp Plus Thermometer
Item #: 68MCTX-B
Welch Allyn Connex 6800 Vital Signs Monitor with Masimo SpO2, Covidien Capnography, SureTemp Plus Thermometry, SureBP Non-invasive Blood Pressure, Pulse Rate, MAP, Custom Scoring, Nurse Call, Four USB Ports for Accessories, Internal 802.11 a/b/g Wireless Radio; 100-240 V, 50-60 Hz AC, IEC Plug Type-B
Added to Your Cart
Product Availability by Store Location
Hours


