Hillrom and Welch Allyn are a part of Baxter.
You searched for "resistor that P15"
Did you mean: register than P15?
Item #: FT12150
FLO-THRU Intraluminal Shunt, is a sterile, single use, disposable one-piece radiopaque silicone tube with atraumatic bulbs shaped at each end. Openings at the ends of the bulbs allow blood to flow through the shunt and distal to the anatomosis. A radiopaq
Item #: FT12275
FLO-THRU Intraluminal Shunt, is a sterile, single use, disposable one-piece radiopaque silicone tube with atraumatic bulbs shaped at each end. Openings at the ends of the bulbs allow blood to flow through the shunt and distal to the anatomosis. A radiopaque tab, which identifies the outer diameter of the bulbs, is attached to the shunt by a tether to faciliate positioning and removal of the shunt. FLO-THRU is packaged in a standard TYVEK double aseptic transfer peel-back pouch. There are five FLO-THRU shunts of equal bulb size per carton. Shown Here: 2.50MM.
Item #: FT12200
FLO-THRU Intraluminal Shunt, is a sterile, single use, disposable one-piece radiopaque silicone tube with atraumatic bulbs shaped at each end. Openings at the ends of the bulbs allow blood to flow through the shunt and distal to the anatomosis. A radiopaq
Item #: FT12175
FLO-THRU Intraluminal Shunt, is a sterile, single use, disposable one-piece radiopaque silicone tube with atraumatic bulbs shaped at each end. Openings at the ends of the bulbs allow blood to flow through the shunt and distal to the anatomosis. A radiopaq
Item #: 50125
FLO-RESTER is a sterile, single use, disposable occluder composed of two silicone rubber bulbs on the distal ends of a flexible shaft. A tab on a tether is attached to the midpoint of the flexible shaft forming a T configuration. FLO-RESTER bulbs and tab
Item #: 50200
FLO-RESTER is a sterile, single use, disposable occluder composed of two silicone rubber bulbs on the distal ends of a flexible shaft. A tab on a tether is attached to the midpoint of the flexible shaft forming a T configuration. FLO-RESTER bulbs and tab
Item #: 50100
FLO-RESTER is a sterile, single use, disposable occluder composed of two silicone rubber bulbs on the distal ends of a flexible shaft. A tab on a tether is attached to the midpoint of the flexible shaft forming a T configuration. FLO-RESTER bulbs and tab
Item #: 50450BIOS
FLO-RESTER is a sterile, single use, disposable occluder composed of two silicone rubber bulbs on the distal ends of a flexible shaft. A tab on a tether is attached to the midpoint of the flexible shaft forming a T configuration. FLO-RESTER bulbs and tab
Item #: 50400
FLO-RESTER is a sterile, single use, disposable occluder composed of two silicone rubber bulbs on the distal ends of a flexible shaft. A tab on a tether is attached to the midpoint of the flexible shaft forming a T configuration. FLO-RESTER bulbs and tab
Item #: 50350
FLO-RESTER is a sterile, single use, disposable occluder composed of two silicone rubber bulbs on the distal ends of a flexible shaft. A tab on a tether is attached to the midpoint of the flexible shaft forming a T configuration. FLO-RESTER bulbs and tab
Item #: 50175
FLO-RESTER is a sterile, single use, disposable occluder composed of two silicone rubber bulbs on the distal ends of a flexible shaft. A tab on a tether is attached to the midpoint of the flexible shaft forming a T configuration. FLO-RESTER bulbs and tab
Item #: 50150
FLO-RESTER is a sterile, single use, disposable occluder composed of two silicone rubber bulbs on the distal ends of a flexible shaft. A tab on a tether is attached to the midpoint of the flexible shaft forming a T configuration. FLO-RESTER bulbs and tab
Item #: H93843055
Oral Labels. Pre-printed Pin-feed Labels for Identification of Oral Medications. “ORAL” imprint in large, faded pink color letters. 2" x 0.5". (50 x 15 mm). (1000/Case)
List Price: $72.45
Item #: 2B7709
CLINIMIX 5/15 sulfite-free (5% Amino Acid in 15% Dextrose) Injection 2000 mL in CLARITY Dual Chamber Container. NDC 0338-1099-04
Item #: C051870160
When there is an active heated humidifier, the Ventilator Mode test can also be performed using the ICU Patient Connector and the Hydrophobic Filter. The ICU Patient Connector replaces the Standard Filter minimizing dead space and resistance added to the circuit and thus improving patient comfort. The Hydrophobic Filter is then required to prevent water condensation to get into the device, due to the absence of the Standard Filter. Reusable: must be replaced daily or after 5 tests, whichever occurs first.
List Price: $210.00
Item #: 2C8862
BURETROL Solution Set with 150 mLValveless Burette with and 4 CLEARLINK Luer Activated Valves (1 in burette), Male Luer Lock Adapter with Retractable Collar. Approximately 60 drops/mL. Approximate length 115" (2.9 m). Contains DEHP. Fluid path is sterile, nonpyrogenic.
Added to Your Cart
Product Availability by Store Location
Hours


