Hillrom and Welch Allyn are a part of Baxter.
You searched for "YOUNG BO 80 DRIP"
Did you mean: your BO 80 drop?
Item #: PG1225
Peri-Guard Repair Patch is derived from bovine pericardium procured from cattle originating in the United States. The pericardium is cross-linked with glutaraldehyde and treated with 1 molar sodium hydroxide for a minimum of 60 minutes at 20-25°C (68-77°F).
Item #: SPG0814
Supple Peri-Guard Repair Patch is derived from bovine pericardium procured from cattle originating in the United States. The pericardium is cross-linked with glutaraldehyde and treated with 1 molar sodium hydroxide for a minimum of 60 minutes at 20-25°C (68-77°F).
Item #: SPG0608
Supple Peri-Guard Repair Patch is derived from bovine pericardium procured from cattle originating in the United States. The pericardium is cross-linked with glutaraldehyde and treated with 1 molar sodium hydroxide for a minimum of 60 minutes at 20-25°C (68-77°F).
Item #: AIN03008
Naloxone Hydrochloride Injection USP, Multiple-Dose Vial 4 mg/10mL (0.4mg/mL), 10 mL x 1. For Intravenous, Intramuscular, and Subcutaneous administration. Carton NDC 36000-310-02
Item #: 2B0081
5% Dextrose Injection, USP, 50 mL VIAFLEX Plastic Container, Quad Pack (4 bags/overwrap). NDC: 0338-0017-11
Item #: 1B6624
10% TRAVASOL (Amino Acid) Injection 1000 mL in VIAFLEX Plastic Container. Pharmacy Bulk Package. Not for Direct Infusion.
Item #: 1B6623
10% TRAVASOL (Amino Acid) Injection 500 mL in VIAFLEX Plastic Container. Pharmacy Bulk Package. Not for Direct Infusion.
Item #: 2B0088
5% Dextrose Injection, USP, 50 mL VIAFLEX Plastic Container, Multi Pack (16 bags/overwrap). NDC 0338-0017-31
Item #: AIN00234
Metoprolol Tartrate Injection, USP, 5mg / 5mL (1 mg/ mL) Sterile Single Dose Glass Vial (10 x 5 mL). For Intravenous Use. NDC 36000-033-10
Recothrom Thrombin topical (Recombinant) is a topical thrombin indicated to aid hemostasis whenever oozing blood and minor bleeding from capillaries and small venules is accessible and control of bleeding by standard surgical techniques (such as suture, ligature, or cautery) is ineffective or impractical in adults and pediatric populations greater than or equal to one month of age.
Tamper-Resistent Add-Port Cap, Red plastic hinged cap, sealed on one end. After additives are made, place Add-Port Cap over additive port and snap closed. Once attached, the Add-Port Cap is designed not to be removed. Non-Sterile.
Item #: FT12150
FLO-THRU Intraluminal Shunt, is a sterile, single use, disposable one-piece radiopaque silicone tube with atraumatic bulbs shaped at each end. Openings at the ends of the bulbs allow blood to flow through the shunt and distal to the anatomosis. A radiopaque tab, which identifies the outer diameter of the bulbs, is attached to the shunt by a tether to faciliate positioning and removal of the shunt. FLO-THRU is packaged in a standard TYVEK double aseptic transfer peel-back pouch. There are five FLO-THRU shunts of equal bulb size per carton. Shown here: 1.25MM.
Item #: FT12275
FLO-THRU Intraluminal Shunt, is a sterile, single use, disposable one-piece radiopaque silicone tube with atraumatic bulbs shaped at each end. Openings at the ends of the bulbs allow blood to flow through the shunt and distal to the anatomosis. A radiopaque tab, which identifies the outer diameter of the bulbs, is attached to the shunt by a tether to faciliate positioning and removal of the shunt. FLO-THRU is packaged in a standard TYVEK double aseptic transfer peel-back pouch. There are five FLO-THRU shunts of equal bulb size per carton. Shown Here: 2.50MM.
Item #: FT12100
FLO-THRU Intraluminal Shunt, is a sterile, single use, disposable one-piece radiopaque silicone tube with atraumatic bulbs shaped at each end. Openings at the ends of the bulbs allow blood to flow through the shunt and distal to the anatomosis. A radiopaque tab, which identifies the outer diameter of the bulbs, is attached to the shunt by a tether to faciliate positioning and removal of the shunt. FLO-THRU is packaged in a standard TYVEK double aseptic transfer peel-back pouch. There are five FLO-THRU shunts of equal bulb size per carton. Shown here: 1.25MM.
Item #: FT12300
FLO-THRU Intraluminal Shunt, is a sterile, single use, disposable one-piece radiopaque silicone tube with atraumatic bulbs shaped at each end. Openings at the ends of the bulbs allow blood to flow through the shunt and distal to the anatomosis. A radiopaque tab, which identifies the outer diameter of the bulbs, is attached to the shunt by a tether to faciliate positioning and removal of the shunt. FLO-THRU is packaged in a standard TYVEK double aseptic transfer peel-back pouch. There are five FLO-THRU shunts of equal bulb size per carton. Shown Here: 2.50MM
.
Item #: EZPE8835
Epinephrine in 0.9% Sodium Chloride Injection, 16 mg/250 mL (64 mcg/mL): Single-Dose VIAFLO Plastic Container (20 bags/carton), Liquid Premix. NDC 0338-0024-20.
Item #: H93824
REPEATER Pump Syringe Filling Fixture. Holds pump tube set for filling single syringes or other luer devices. Suction feet hold the fixture securely to base of laminar flow hood. Clear anodized aluminum, 2” x 2.5” x 3.5’’ (51 mm x 64 mm x 89 mm)
Added to Your Cart
Product Availability by Store Location
Hours


