Hillrom and Welch Allyn are a part of Baxter.
You searched for "XAM MONITorING or XAM power ENTERPRISE SYDNEY"
Item #: 2N3383
Protective cap, female adapter, on/off clamp, Luer lock adapter and vented cap For the administration of blood, blood components or solutions from a container into the patient's vascular system through a vascular access device.
Item #: 2C4014
Decanting Set with Clamp. Approximate Length 9.2" (23 cm). For use with Baxter irrigating solutions in plastic containers such as UROMATIC or ARTHROMATIC plastic containers. Contains DEHP. Sterile Package, Nonpyrogenic.
Item #: 2H8865
BURETROL Add-On Set with 150 mL Valveless Burette, 1 CLEARLINK Luer Activated Valve (in burette) and Slide Clamp. Approximate Length 17" (43 cm). Spike adapter contains DEHP; remainder of set does not contain DEHP. Fluid path is sterile, nonpyrogenic. This Add-On set must be used with an administration set.
BURETROL Add-On Set, 150 mL Valveless Burette, INTERLINK Injection Site and slide clamp, 17" (43 cm)
Item #: 2H7565
BURETROL Add-On Set with 150 mL Valveless Burette, 1 INTERLINK Injection Site (in burette) and Slide Clamp. Approximate length 17" (43 cm). Adapter contains DEHP; remainder of set does not contain DEHP. Fluid path is sterile, nonpyrogenic. This Add-On set must be used with an administration set.
Item #: 2C8851
Nitroglycerin Set DUO-VENT Spike with Polyethylene Lined Tubing and CLEARLINK Luer Activated Valve, Male Luer Lock Adapter. Approximately 60 drops/mL. Approximate Length 103" (2.6 m). Sterile Fluid Path. The PVC pump segment and outer layer of polyethylene lined tubing contain DEHP; Remainder of fluid path does not contain DEHP.
Nitroglycerin Set DUO-VENT Spike with Polyethylene Lined Tubing and INTERLINK Injection Site, Male Luer Lock Adapter, Approximately 60 drops/mL. Approximate length 103" (2.6 m). Sterile Fluid Path. The PVC pump segment and outer layer of polyethylene lined tubing contain DEHP; Remainder of fluid path does not contain DEHP.
Item #: 2E7554
Solution Set Non-Vented Spike, Male Epidural Non-Luer Lock Adapter (NRFit). For Epidural Use. Approximately 60 drops/mL. Approximate length 108 (2.8 m). Contains DEHP. Sterile Package. Nonpyrogenic.
Secondary Medication Set, DUO-VENT, INTERLINK Luer Lock Cannula (detached). 10 drops/mL. 37" (95 cm)
Item #: 2C7452
Secondary Medication Set with DUO-VENT Spike, INTERLINK Luer Lock Cannula (detached), Male Luer Lock Adapter. Hanger for primary solution container is provided. Approximately 10 drops/mL. Approximate length 37" (95 cm). Contains DEHP. Fluid path is sterile, nonpyrogenic.
Paclitaxel Set, Vented, 0.2 Micron Filter, CLEARLINK Luer Activated Valve, 10 drops/mL, 107" (2.7 m)
Item #: 2C8857
Paclitaxel Set Vented Spike with Polyethlyene Lined Tubing and CLEARLINK Luer Activated Valve, 0.2 Micron Filter, Male Luer Lock Adapter. Approximately 10 drops/mL. Approximate Length 107" (2.7 m). Non-DEHP Pump Segment. Sterile Fluid Path. Fluid path does not contain DEHP; outer layer of polyethylene lined tubing contains DEHP.
Item #: UC8519
CONTINU-FLO Solution Set with DUO-VENT Spike, 2 CLEARLINK Luer Activated Valves, Backcheck Valve, Male Luer Lock Adapter with Retractable Collar. Approximately 10 drops/mL. Approximate Length 114" (2.9 m), 19.1 mL. The PVC pump segment contains DEHP; Remainder of set does not contain DEHP. Fluid path is sterile, nonpyrogenic.
Item #: 2C7558
Paclitaxel Set Non-Vented Spike with Polyethylene Lined Tubing and INTERLINK Injection Site, 0.2 Micron Filter, Male Luer Lock Adapter. Approximately 10 drops/mL. Approximate length 108" (2.7 m). Non-DEHP Pump Segment. Sterile Fluid Path. Fluid path does not contain DEHP; outer layer of polyethylene lined tubing contains DEHP.
Item #: 2R8858
Paclitaxel Set Non-Vented Spike with Polyethylene Lined Tubing and CLEARLINK Luer Activated Valve, 0.2 Micron Filter, Male Luer Lock Adapter. Approximately 10 drops/mL. Approximate Length 107" (2.7 m). Non-DEHP Pump Segment. Sterile Fluid Path. Fluid path does not contain DEHP; Outer layer of polyethylene lined tubing contains DEHP.
Item #: 2C6571
CONTINU-FLO Solution Set with Non-Vented Spike, 0.2 Micron Filter, 2 INTERLINK Injection Sites, Backcheck Valve and Male Luer Lock Adapter Retractable Collar. Approximately 10 drops/mL. Approximate Length 105" (2.7 m). Contains DEHP. Fluid path is sterile, nonpyrogenic.
Solution Set with Non-Vented Spike, CLEARLINK Luer Activated Valve and Male Luer Lock Adapter with Retractable Collar. Approximately 10 drops/mL. Approximate Length 76 (1.9 m). Contains DEHP. Fluid path is sterile, nonpyrogenic.
Item #: 2R8480
Solution Set with DUO-VENT Spike, 0.2 Micron Downstream Filter, CLEARLINK Luer Activated Valve and Male Luer Lock Adapter with Retractable Collar. Approximately 10 drops/mL. Approximate Length 103 (2.6 m). Non-DEHP. Fluid path is sterile, nonpyrogenic.
Straight-Type Catheter Extension Set, Micro-volume, Male Luer Lock Adapter. Approximate Volume 0.44 mL. Approximate Length 10 (25 cm). Non-DEHP. Sterile Package, Nonpyrogenic.
Solution Set with Non-Vented Spike, 2 INTERLINK Injection Sites and Male Luer Lock Adapter with Retractable Collar. Approximately 10 drops/mL. Approximate Length 101" (2.6 m). Contains DEHP. Fluid path is sterile, nonpyrogenic.
Added to Your Cart
Product Availability by Store Location
Hours


