Hillrom and Welch Allyn are a part of Baxter.
text.productList.page.partNumber 1C8160
Solution Set with Non-Vent Spike and Male Luer Lock Adapter. Approximately 10 drops/mL. Approximate Length 69" (1.7 m). Contains DEHP. Sterile package, nonpyrogenic.
text.productList.page.partNumber 2C6256
CONTINU-FLO Solution Set with Non-Vented Spike, 2 CLEARLINK Luer Activated Valves, Backcheck Valve and Male Luer Lock Adapter with Retractable Collar. Approximately 10 drops/mL. Approximate length 88" (2.2 m). Plus Large Bore 4-Way Stopcock Manifold Extension Set with CLEARLINK Luer Activated Valve and Male Luer Lock Adaptor with Retractable Collar. Approximate Volume 6.1 mL. Approximate Length 36" (92 cm). Contains DEHP. Sterile package, nonpyrogenic.
text.productList.page.partNumber 2C8750
Y-Type Blood/Solution Set with Standard Blood Filter (170 to 260 Micron Filter), 1 CLEARLINK Luer Activated Valve, and Male Luer Lock Adapter with Retractable Collar. Approximately 10 drops/mL. Approximate length 112" (2.8 m). Contains DEHP. Fluid path is sterile, nonpyrogenic.
text.productList.page.partNumber 1C8109
Solution Set with Non-Vent Spike and Male Luer Lock Adapter. Approximately 10 drops/mL. Approximate Length 101" (2.6 m). Contains DEHP. Fluid path is sterile, nonpyrogenic.
text.productList.page.partNumber 2C6537
CONTINU-FLO Solution Set with Non-Vented Spike, 3 INTERLINK Injection Sites, Backcheck Valve and Male Luer Lock Adapter with Retractable Collar. Approximately 10 drops/mL. Approximate Length 110" (2.8 m). Contains DEHP. Fluid path is sterile, nonpyrogenic.
text.productList.page.partNumber 2H8537
CONTINU-FLO Solution Set with Non-Vented, 3 CLEARLINK Luer Activated Valves, Backcheck Valve and Male Luer Lock Adapter with Retractable Collar. Approximately 10 drops/mL. Approximate Length 109" (2.8 m). Non-DEHP. Fluid path is sterile, nonpyrogenic.
text.productList.page.partNumber 2R8401
Solution Set with Non-Vented Spike, CLEARLINK Luer Activated Valve and Male Luer Lock Adapter with Retractable Collar. Approximately 10 drops/mL. Approximate Length 76" (1.9 m). Non-DEHP. Fluid path is sterile, nonpyrogenic.
text.productList.page.partNumber 2R8858
Paclitaxel Set Non-Vented Spike with Polyethlyene Lined Tubing and CLEARLINK Luer Activated Valve, 0.2 Micron Filter, Male Luer Lock Adapter. Approximately 10 drops/mL. Approximate Length 107" (2.7 m). Non-DEHP Pump Segment. Sterile Fluid Path. Fluid path does not contain DEHP: Outer layer of polyethylene lined tubing contains DEHP.
text.productList.page.partNumber 2C7558
Paclitaxel Set Non-Vented Spike with Polyethylene Lined Tubing and INTERLINK Injection Site, 0.2 Micron Filter, Male Luer Lock Adapter. Approximately 10 drops/mL. Approximate length 108" (2.7 m). Non-DEHP Pump Segment. Sterile Fluid Path. Fluid path does not contain DEHP; outer layer of polyethylene lined tubing contains DEHP.
text.productList.page.partNumber 2C8537
CONTINU-FLO Solution Set with Non-Vented Spike, 3 CLEARLINK Luer Activated Valves, Backcheck Valve and Male Luer Lock Adapter with Retractable Collar. Approximately 10 drops/mL. Approximate Length 120". Contains DEHP. Fluid path is sterile, nonpyrogenic.
text.productList.page.partNumber 2R1145
IV Fat Emulsion Administration Set with Non-Vented Spike and Male Luer Lock Adapter with Retractable Collar. Approximately 10 drops/mL. Approximate Length 86" (2.2 m). Non-DEHP. Fluid path is sterile, nonpyrogenic.
text.productList.page.partNumber 2R8537
CONTINU-FLO Solution Set with Non-Vented Spike, 3 CLEARLINK Luer Activated Valves, Backcheck Valve and Male Luer Lock Adapter with Retractable Collar. Approximately 10 drops/mL. Approximate Length 120" (3 m). Non-DEHP. Fluid path is sterile, nonpyrogenic.
已添加至购物车
产品供货(按店铺位置)
小时


